What is a silent generator? Noise, design and hire options in South Africa

Key Takeaways

  • A silent generator is a backup power solution with a sound‑attenuated enclosure, tuned airflow, exhaust silencers, and anti‑vibration mounts to cut noise at source while delivering stable power.
  • Typical noise performance is 60–75 dB(A) at 7 m (ISO 8528‑10), far quieter than open‑set diesel units (85–100 dB[A]); align placement with WHO and SANS 10103 community noise limits.
  • Main types: canopy diesel generator for offices, retail, events and estates; containerised generator for industrial loads and long runtimes in demanding environments.
  • Choose and site wisely: size for 60–80% load, verify factory dB(A) reports, avoid reflective walls, and specify AVR/low‑THD alternators; proven OEM options include Cummins and Perkins.
  • In South Africa, you can opt for generator hire or ownership; ensure compliance (ISO/SANS/IEC), schedule generator maintenance services, and validate on‑site noise to keep within local by‑laws.

What Is A Silent Generator?

A silent generator uses acoustic engineering to cut noise while delivering stable power for sensitive sites and everyday operations. It combines a sound‑attenuated enclosure with tuned airflow, exhaust treatment, and vibration control to lower decibels at the source.

How Silent Design Works

  • Enclosure. A lined steel canopy blocks airborne noise and prevents panel resonance across key octave bands.
  • Intake. A labyrinth air path with acoustic foam slows airflow and reduces intake roar at high load.
  • Exhaust. A residential or critical grade silencer trims exhaust tones and removes dominant low frequency peaks.
  • Mounts. Anti‑vibration mounts isolate the engine alternator set from the frame and ground.
  • Cooling. Oversized radiators and low‑tip‑speed fans maintain airflow with less fan noise.
  • Control. Electronic governors and AVRs stabilise speed and voltage which smooths tonal noise under transient loads.

Typical Noise Performance

These figures reflect common factory ratings measured at 7 m in free field conditions under ISO 8528‑10 noise test methods.

Generator typeRated noise at 7 m dB(A)Test reference
Silent generator canopy set60–75ISO 8528‑10
Containerised silent generator65–78ISO 8528‑10
Open‑set diesel generator85–100ISO 8528‑10
Outdoor comfort guideline55 targetWHO Environmental Noise Guidelines 2018

Silent Generator Types

  • Canopy diesel generator. Compact acoustic canopy suits offices retail sites data rooms and small food production lines.
  • Containerised generator. ISO container with engineered baffles suits industrial diesel generator duties and long runtimes.
  • Quiet diesel generator. Low‑noise package for standby generator roles where backup power solutions must meet local limits.

When A Silent Generator Fits

  • Sensitive industries. Food production plants laboratories and medical facilities protect quality and compliance when noise stays low.
  • Commercial spaces. Offices malls and hospitality sites maintain worker comfort and customer experience during outages.
  • Events and campuses. Schools events and public venues meet municipal by‑laws and keep communication clear.
  • Urban backup. High‑density areas run standby power at night while respecting neighbour limits.

Fuel System And Engine Choices

  • Diesel platforms. Proven fuel energy density supports long runtime duty cycles and fast refuelling in remote areas.
  • OEM diesel generator options. Cummins diesel generator and Perkins diesel generator platforms pair with tuned exhaust and mounts for low noise.
  • Alternator pairing. Low‑harmonic alternators with digital AVR reduce electrical noise that can drive mechanical chatter.
  • Load management. Smart controllers stage loads to avoid sharp transients that raise acoustic output.

Hire And Ownership Paths

  • Generator hire. Short or long term rental covers peak demand projects and outage windows across South Africa.
  • Generator rental South Africa. Fleet options span canopy diesel generator units and containerised generator sets for construction and manufacturing.
  • Standby installation. Fixed systems support backup power solutions for facilities that require continuous operations.
  • Generator maintenance services. Planned services cover fluids filters belts control panel calibration and voltage regulation checks.

Standards And Compliance

  • Measurement. ISO 8528‑10 defines test environments positions and metrics for generator noise ratings.
  • Safety. IEC 60204‑1 and relevant SANS standards guide electrical safety for installed sets in South Africa.
  • Environment. WHO Environmental Noise Guidelines inform site placement and operational limits near residences.

Elegen Scope And Expertise

  • Manufacturing. We design build and test silent generator packages for industrial commercial and backup use across Africa.
  • Engines. We integrate authorised OEM engines including Cummins G‑Drive and Perkins with noise‑optimised systems.
  • Support. We deliver end‑to‑end services across design fabrication testing delivery installation and support with on‑site and in‑house teams.
  • Brands. We operate as Elegen South Africa with experienced technicians and control panel upgrade capability for legacy fleets.

How Silent Generators Work

Silent generator packages combine acoustic engineering and low-noise power electronics to cut sound at source and along airflow paths. We apply these principles across canopy diesel generator sets and containerised generator builds for backup power solutions in sensitive sites.

Acoustic Enclosures And Insulation

Sound-attenuated housings reduce airborne and structure-borne noise across the full frequency range. We use dense composite panels, mineral wool liners, and mass-loaded barriers around the engine, alternator, and exhaust paths.

  • Managing airflow, we route intake and discharge through labyrinth ducts with tuned baffles and splitter silencers.
  • Isolating vibration, we fit anti-vibration mounts, flexible exhaust bellows, and resilient cable glands at all contact points.
  • Controlling resonance, we select panel thickness, perforation ratios, and cavity depths based on octave-band targets for each silent generator.
  • Optimising service access, we design sealed inspection doors, quick-release panels, and gasketed cable entries across canopy diesel generator and containerised generator formats.

Our builds support industrial diesel generator duties in food production, commercial premises, and other noise-sensitive environments in Elegen South Africa projects.

Engine Technology And Inverter Systems

Low-noise performance starts with efficient combustion and smooth alternator output. We integrate OEM diesel generator platforms with matched control to stabilise rpm and reduce tonal peaks across load steps.

  • Selecting engines, we specify Cummins diesel generator G-Drive packages and Perkins diesel generator options with electronic fuel control and optimised turbocharging.
  • Refining exhaust, we size reactive or hybrid silencers and fit DOC or DPF elements where site emissions plans permit.
  • Stabilising voltage, we deploy AVR-controlled alternators with low total harmonic distortion for quiet diesel generator use in sensitive electronics.
  • Enhancing acoustics, we offer inverter-based outputs on small sets for variable-speed operation at light loads, then we lock to fixed speed for prime or standby generator duty on larger frames.
  • Streamlining uptime, we align generator maintenance services with on-site access, part replacements, control panel upgrades, and voltage regulation checks across generator hire fleets.

We engineer Elegen packages to meet low-noise criteria across generator rental South Africa deployments, from short-term generator hire to permanent installations, using proven Cummins, Perkins, and other OEM integrations.

Key Benefits And Trade-Offs

Silent generator packages cut noise without sacrificing reliability. We balance acoustic gains with cost, size, airflow, and service access.

Noise Levels And Regulations

Noise ratings define placement and compliance for a silent generator in South Africa. We reference SANS 10103 community noise guidelines, WHO Environmental Noise Guidelines 2018, and local by-laws for day and night limits.

  • Selecting: Choose a quiet diesel generator with a verified dB(A) at 7 m test to match site limits and neighbours.
  • Locating: Place a canopy diesel generator away from hard walls and openings for lower reflected noise.
  • Enclosing: Specify a sound attenuated enclosure with labyrinth air paths, dense panels, and anti vibration mounts.
  • Verifying: Request a factory noise test report to ISO 3744 or ISO 9614 with operating load noted.

Noise benchmarks and common limits

ItemTypical valueNotes
Residential night limit40 to 45 dB(A)WHO 2018 and SA municipal by-laws
Residential day limit50 to 55 dB(A)SANS 10103 guidance
Office interior target40 to 50 dB(A)SANS 10103 guidance
Silent generator at 7 m60 to 70 dB(A)Sound attenuated canopy load dependent
Industrial diesel generator at 7 m75 to 85 dB(A)Standard enclosure load dependent

Trade offs exist between noise level and footprint. Larger airflow paths and thicker panels lower dB(A) at the cost of size and weight. Lower fan speeds reduce noise at the cost of higher operating temperatures. Tighter acoustic packs lower broadband noise at the cost of more frequent cleaning in dusty sites.

Compliance requires documentation first and acoustic treatment second. Verified noise data gives planning certainty if by-laws set strict night limits.

Efficiency, Fuel, And Maintenance

Fuel efficiency guides total cost for a standby generator or backup power solutions. We prioritise load matching and clean power quality to protect sensitive equipment in food production and similar environments.

  • Right-sizing: Match kVA to typical and peak load to hold 60 to 80 percent loading during outages.
  • Optimising: Use electronic governors and AVR or digital excitation for stable Hz and voltage.
  • Selecting: Choose an OEM diesel generator from proven platforms for parts access across Africa.
  • Maintaining: Schedule generator maintenance services with oil, filters, coolant, belts, and battery checks.

Service and ownership options support different budgets. Generator hire covers short projects in events, retail, and temporary sites across kVA ranges. Generator rental South Africa supports seasonal peaks in agriculture and processing. Containerised generator builds enable rapid deployment with integrated fuel tanks and attenuation.

Engine and alternator choices influence noise and cost

  • Pairing: Consider Cummins diesel generator G-Drive, Perkins diesel generator, or Volvo Penta generator options for duty cycle and load response.
  • Enclosing: Use a canopy diesel generator for moderate noise control and fast site setup.
  • Upgrading: Add control panel upgrades and voltage regulation systems for cleaner output under variable loads.
  • Servicing: Use on site and in house support for part replacements, control panel upgrades, and voltage regulation checks.

Efficiency gains depend on load factor first and fuel type second. Diesel platforms deliver strong torque at low rpm which reduces acoustic signature at constant speed. Low harmonic alternators reduce electrical noise and heat which stabilises acoustic performance under nonlinear loads. Fuel burn rates vary with load by a steep curve so undersized or oversized sets increase litres per kWh.

Standards anchor safe and efficient operation. We reference ISO 8528 for performance and rating, IEC 60034 for alternators, and SANS 10086 for engine installations. Elegen South Africa packages integrate these controls across design, engineering, fabrication, testing, delivery, installation, and support.

Common Applications

Silent generator power fits sites where low noise, clean supply, and tight layouts come together. We match kVA, enclosure type, and acoustic class to the environment, then we support the asset with generator maintenance services.

Residential And Recreational Use

  • Protects home comfort during outages with a standby generator and automatic transfer, then limits noise to 50–65 dB(A) at 7 m using a canopy diesel generator.
  • Reduces flicker and THD for sensitive electronics, then pairs an OEM diesel generator alternator with AVR and low-harmonic settings.
  • Fits compact footprints in estates, lodges, and campsites, then uses compact enclosures and side-lifting access for service.
  • Covers short breaks or seasonal peaks via generator hire, then scales from 15–60 kVA quiet diesel generator sets for light household and lodge loads.
  • Integrates trusted platforms for reliability, then selects Cummins diesel generator or Perkins diesel generator packages verified by Elegen South Africa.

Commercial, Construction, And Events

  • Supports food production lines, data rooms, and retail fridges with backup power solutions, then applies acoustic treatment that meets SANS 10103 targets for mixed-use areas.
  • Powers cranes, pumps, and site cabins with an industrial diesel generator fleet, then deploys containerised generator units for 125–1000 kVA projects.
  • Serves concerts, markets, and broadcasts with a silent generator mobile layout, then combines labyrinth air paths with anti-vibration mounts to cut stage-side noise bleed.
  • Enables fast deployment through generator rental South Africa, then uses pre-tested sets with load-test certificates, spill kits, and earth stakes.
  • Streamlines uptime through generator maintenance services, then schedules on-site servicing, part replacements, control panel upgrades, and voltage regulation.

Typical silent generator profiles by application

ApplicationTypical kVA RangeEnclosure TypeNoise Level dB(A) at 7 mDaily Runtime Example
Homes, estates15–45Canopy50–602–6 h
Lodges, campsites20–60Canopy55–653–8 h
Retail, offices40–125Canopy60–704–10 h
Events, broadcast60–200Canopy55–656–12 h
Construction sites125–500Containerised65–758–20 h
Food production plants200–1000Containerised65–7512–24 h
  • Aligns silent generator selection with site rules and noise zones first, then finalises placement clear of walls to reduce reflections.
  • Matches load profiles to engine class first, then narrows to Cummins diesel generator, Perkins diesel generator, or Volvo Penta generator per duty cycle.
  • Chooses canopy diesel generator for suburbs and events first, then uses containerised generator sets for heavy industrial yards and plant rooms.
  • Secures flexibility with generator hire for projects and peaks first, then moves to ownership once baseload stabilises under Elegen Generators support.

Choosing The Right Silent Generator

Choose a silent generator by matching load, noise targets, and site limits. Align power class, runtime, and format with your usage profile and space.

Sizing, Runtime, And Fuel Type

Size the generator to run at 60–80% of rated kVA at steady state for best efficiency and lower noise. Map all loads, list examples like compressors, chillers, conveyors, ovens, data racks, and compute start currents for motors using 2–6x running amps for across‑the‑line starts or 1.5–2.5x with soft starters and VSDs. Plan headroom for transient dips from lifts, pumps, and HVAC. Select low‑THD alternators for sensitive equipment, examples include PLCs, VFDs, and servers.

Pick runtime targets that match risk, examples include 8 hours overnight, 12 hours shift cover, and 24 hours day‑night autonomy. Use integrated bunded tanks for short runs, use external tanks for long runs, and use telemetry for refuelling control. Choose diesel for most sites due to energy density, support, and cold‑start performance in South Africa. Specify an OEM diesel generator platform for parts and acoustic maps, examples include Cummins diesel generator G‑Drive, Perkins diesel generator, and Volvo Penta generator sets. Select enclosure types to meet noise and footprint goals, examples include canopy diesel generator for yard installs and containerised generator for plant rooms and high kVA.

We support generator hire and generator rental South Africa for trials before purchase, and we include generator maintenance services across on‑site and in‑house options. We integrate AVR, AMF, and ATS in line with SANS 10142 wiring rules and align noise placement with SANS 10103 community noise guidance and WHO environmental noise guidance.

kVA classTypical loadsStart current plan75%‑load fuel use L/hIndicative tank LIndicative runtime hNoise at 7 m dB(A)
15–30Homes, lodges, small fridges, POS, lights2–3x with soft starts3–6100–20016–4050–60
45–80Cold rooms, small lines, IT rooms, site cranes2–4x mixed8–16250–50016–4055–65
100–160Food process, pumps, HVAC, welding bays3–5x motors18–30500–80016–3260–68
200–350Large chillers, conveyors, crushers, data halls3–6x motors40–70800–1 50012–3065–72

Notes: values are typical at sea level and 25°C for quiet diesel generator sets with sound‑attenuated enclosures, and acoustic results vary by installation and placement.

We build and support OEM diesel generator packages under Elegen South Africa, and we’re GOEM for Cummins with OEM supply for Stamford and Volvo. We offer Elegen Generators in canopy and container forms with verified acoustic data, and we align service intervals to engine OEM schedules.

Portability, Features, And Safety

Pick formats that match deployment and access.

  • Choose canopy sets for compact footprints, choose container sets for high kVA and harsh sites, choose skid frames for static plinths.
  • Choose trailer‑mounted units for frequent moves, choose forklift pockets and lift lugs for yard handling, choose quick‑connect camlocks for fast hook‑up.
  • Choose external bulk tanks for long runtime, choose bunded bases for spill control, choose double‑wall lines for safety.

Pick features that protect loads and cut noise.

  • Specify low‑THD alternators for clean power, specify AVR and digital governors for tight voltage and frequency, specify AMF and ATS for standby generator changeover.
  • Specify control panel upgrades for remote monitoring, specify phase‑rotation and earth‑fault alarms for protection, specify load‑sharing for parallel sets.
  • Specify intake and exhaust baffles for quieter operation, specify anti‑vibration mounts for structure‑borne control, specify labyrinth airflow for better attenuation.

Pick safety controls that pass compliance.

  • Fit certified breakers for overcurrent protection, fit E‑stops at access points, fit fire detection in containers.
  • Allow clear airflow paths around intakes and exhausts, allow 1–2 m service clearance on doors, allow hot surface guards on exhausts.
  • Ground the frame per SANS 10142, ground neutral as per site earthing design, ground fences and bunds where required.

We supply backup power solutions through generator hire or purchase with full support. We cover inspection, part replacements, control panel upgrades, and voltage regulation across our generator maintenance services. We size, install, and support silent generator packages for food production, sensitive sites, and general industrial use across Africa.

Installation And Best Practices

Silent generator installs prioritise airflow, structure, and acoustic control. We design placements that protect people, assets, and uptime across Elegen South Africa projects.

Placement, Ventilation, And Exhaust

Correct siting reduces noise, heat, and risk in one step. We position the silent generator away from reflective walls and openings, then we create straight airflow paths that avoid recirculation.

  • Locate: place the canopy diesel generator or containerised generator 3–5 m from occupied spaces, place the unit clear of doors and windows.
  • Isolate: set anti-vibration mounts on a flat reinforced slab, set cable routes with flexible links that avoid hard coupling.
  • Ventilate: size inlet and outlet louvres to engine airflow, size the free area to match OEM diesel generator data.
  • Duct: route hot air away from intakes, route airflow with smooth bends that keep velocity below 8 m/s.
  • Exhaust: discharge above roofline where practical, discharge 1 m above the highest adjacent opening.
  • Shield: add acoustic fences only after airflow validation, add panels with sound-rated gaps and seals.
  • Protect: fit rain hoods and bird screens, fit spark arrestors on diesel generator exhausts where required by site rules.
  • Access: keep 1 m service clearance on all sides, keep 1.5 m at control panels and switchgear.

We align distances and airflow with site risk, we follow SANS 10089 fuel storage rules where bulk tanks sit near plant. We fix earthing to SANS 10142, we bond neutral and earth as the changeover scheme requires. We confirm cable sizing and fault levels with the switchboard designer.

Noise and heat drop when placement and ventilation match the load. We use OEM data for Cummins diesel generator, Perkins diesel generator, and Volvo Penta generator platforms to set airflow, backpressure, and exhaust routing.

Typical siting and airflow targets

ParameterTarget
Service clearance1.0–1.5 m
Intake face velocity≤ 2.5 m/s
Discharge duct velocity≤ 8.0 m/s
Exhaust outlet heightRoofline or +1.0 m above openings
Minimum setback from offices3–5 m

Noise Testing And Compliance

On-site noise checks confirm the silent generator meets limits at the boundary. We measure A‑weighted sound levels at 1 m and at the property line under steady load.

  • Measure: log dB(A) at 1 m, measure at 4 cardinal points, measure at the nearest receptor.
  • Compare: benchmark against SANS 10103 community noise limits, compare against municipal by-laws.
  • Verify: confirm LwA and 1 m ratings against OEM plates, confirm attenuator and enclosure class.
  • Adjust: tune airflow with baffles, adjust exhaust with higher-grade silencers.
  • Isolate: add anti-vibration upgrades, isolate cable trays and fuel lines that bridge structure.
  • Document: record load, rpm, ambient, and ground type, document instrumentation class and calibration.

We test during representative load, we test with doors and panels closed, we avoid wind and rain that skew readings. We model reflections near walls and canopies, then we add absorptive linings where reflections exceed targets.

Where community limits apply we target 45–55 dB(A) night at the receptor, where industrial limits apply we target 60–70 dB(A) day. We plan acceptance tests during generator hire and during handover for permanent backup power solutions. We include periodic checks within generator maintenance services to keep noise within spec across service life.

For rental in generator rental South Africa programmes we publish verified noise data per unit, for quiet diesel generator sets we include boundary forecasts by kVA class. We keep compliance records for Elegen projects across Africa, and we align test reports with client HSE files and local authority submissions.

Conclusion

Conclusion centres on selecting, siting, and supporting a silent generator for compliant, low-noise backup power in South Africa.

  • Match load to 60–80% of rated kVA for efficiency, stability, and lower noise.
  • Verify a declared dB(A) at 7 m, per SANS 10103 context and WHO community noise guidance.
  • Place units 5–10 m from occupied spaces, behind a barrier, on anti-vibration mounts.
  • Specify an OEM diesel generator with low-THD alternator for clean power to sensitive equipment.
  • Choose a canopy diesel generator for compact sites, or a containerised generator for high kVA and service access.
  • Plan generator hire for short outages, or ownership for continuous or mission‑critical backup power solutions.
  • Schedule generator maintenance services on OEM intervals, including filters, coolant, belts, control panel checks, and voltage regulation tests.
  • Confirm fuel burn and runtime at the target load, with day tank sizing that meets site autonomy targets.
ParameterRecommended targetContext note
Operating load60–80% of kVAReduces wet stacking, improves efficiency
Residential noise50–60 dB(A) at 7 mTypical for a quiet diesel generator in housing estates
Commercial noise60–70 dB(A) at 7 mSuits retail, offices, events
Setback distance5–10 mCuts reflected noise and heat at façades
THD at bus≤5%Limits risk to PLCs, VSDs, IT loads
  • Select engine platforms with proven parts support, for example an OEM diesel generator based on Cummins diesel generator, Perkins diesel generator, or Volvo Penta generator.
  • Pair alternators with low harmonic distortion, for example Stamford class H windings with AVR sensing at the terminals.
  • Align format to environment, for example canopy IP ratings for weather, or container airflow for high ambient temperatures.
  • Validate noise on site with a Class 1 meter at 7 m, at 50% and 75% load, across four quadrants.
  • Integrate safety and compliance, for example SANS electrical clearances, bonded neutral configuration, exhaust routing away from air intakes.

Elegen South Africa supports generator rental South Africa for time-bound projects, and turnkey deployments that cover design, fabrication, FAT, delivery, installation, and lifecycle support. Our silent generator packages, from small standby generator sets to large industrial diesel generator systems, align to food production, sensitive process rooms, and general commercial sites. Our teams deliver on-site assistance, part replacements, control panel upgrades, and voltage regulation services across Africa, and our generator hire fleet spans multiple kVA bands for rapid deployment.

Elegen | Generator Manufacturer & Supplier In South Africa

Address: 23/24 Mountjoy St, Wilbart, Edenvale, 1609
Phone: 011 455 4900
Google Maps: Find us here

Frequently Asked Questions

What is a silent generator?

A silent generator is a power unit engineered to minimise noise using sound‑attenuated enclosures, smart airflow, and anti‑vibration mounts. It delivers reliable backup or prime power with reduced dB(A), making it suitable for homes, events, food production, and urban sites. Many models pair diesel engines with low‑harmonic alternators to keep electrical noise (THD) low for sensitive equipment.

How quiet are silent generators?

Typical silent generators operate around 50–65 dB(A) at 7 metres for residential sizes and 60–75 dB(A) for larger commercial units. Exact levels depend on enclosure quality, airflow design, and load. Always verify manufacturer noise ratings to ISO/SANS test methods and confirm on‑site with a calibrated meter.

Why are silent generators popular in South Africa?

Frequent power instability and tight urban layouts demand low‑noise, dependable power. Silent generators meet SANS 10103/WHO noise limits, protect sensitive equipment with clean power, and suit food production, events, retail, construction, and data rooms. Flexible hire and support services make deployment fast and cost‑effective.

What kVA size do I need?

Size for 60–80% load during typical operation. Add starting currents for motors, chillers, and compressors, and include growth and diversity factors. Homes often use 8–30 kVA; commercial sites 40–250 kVA; industrial/process loads 250–1,000+ kVA. Ask for a load audit to match kVA, voltage, and phase.

Are diesel silent generators better?

Diesel offers high energy density, robust performance, wide parts availability, and efficient fuel burn under varying loads. Paired with low‑THD alternators and modern controls, diesel platforms deliver low noise and stable voltage/frequency for sensitive electronics. Alternative fuels may suit niche cases but can cost more.

Can I hire a silent generator short‑ or long‑term?

Yes. You can rent by day, week, or multi‑month with options across compact residential to high‑capacity industrial kVA ranges. Reputable providers include delivery, cabling, commissioning, on‑site support, refuelling, and swap‑outs. Long‑term hire can include fixed pricing, maintenance, and remote monitoring.

What support services should I expect?

Look for on‑site assistance, scheduled maintenance, emergency call‑outs, part replacements, fuel management, control panel upgrades, voltage regulation, and remote telemetry. Proper support reduces downtime, keeps noise within spec, and protects connected equipment.

How do I ensure compliance with noise regulations?

Reference SANS 10103 community noise guidelines and WHO recommendations. Confirm the generator’s certified noise rating, site it 5–10 metres from occupied spaces, use anti‑vibration mounts, and manage airflow and exhaust paths. Conduct on‑site noise tests at agreed measurement points and times.

Where should I place a silent generator?

Place it on a level, ventilated pad, 5–10 metres from doors, windows, and neighbours. Avoid reflective corners; allow service clearances; use anti‑vibration mounts; and direct exhaust away from people and intakes. Provide clean airflow in and baffles or labyrinth paths out to cut noise.

How do silent generators reduce noise?

They combine dense composite enclosures, acoustic insulation, labyrinth air paths, tuned intakes/exhausts, and anti‑vibration mounts. Low‑noise fans, optimised engine speed, and low‑THD alternators also reduce mechanical and electrical noise. Correct siting completes the noise control.

Do silent generators produce clean power for electronics?

Yes—when paired with quality AVR or inverter systems and low‑THD alternators. This keeps voltage, frequency, and harmonic distortion stable for UPSs, PLCs, servers, and medical or food‑grade equipment. Proper sizing prevents under‑loading and wet‑stacking, further improving power quality.

What maintenance is required?

Follow OEM intervals: regular oil and filter changes, coolant and fuel checks, battery tests, belt/hoses inspection, and load testing. Keep airways clear, inspect acoustic panels and mounts, and verify noise and emissions after service. Log fuel burn versus load to catch issues early.

What affects total cost of ownership?

Key drivers include fuel burn at typical load, service intervals, parts availability, noise enclosure quality, alternator THD, and remote monitoring. Correct sizing (60–80% load), efficient diesel platforms, and good airflow design lower running costs and noise over time.

Who is Elegen and what do they offer?

Elegen designs and manufactures silent generator packages in South Africa, with rental and turnkey solutions across Africa. Services include sizing, installation, control upgrades, voltage regulation, on‑site support, parts, and maintenance. Their systems target low‑noise performance and compliance for residential, commercial, and industrial sites.